一区二区无码动漫在线观看_亚洲免费福利视须_国产成人午夜福利不卡在线观看_国内在线 欧美亚洲_久久婷婷丁香七月色综合啪_中文免费无码乱伦_午夜偷拍精品用户偷拍卧室_亚洲成人少妇激情_免费无遮挡又黄又爽男同网站_丰满风流护士长BDA片

Tower Elevator

Tower Elevator

The tower elevator is mainly used as the special elevator for the structure facilities at the independent height (100-500?meters) with special purpose. It is designed with the unique tractor equipped downwards and anti-swing and anti-strong?interference signal processing system. Due to the extension of the steel rope, it is specially designed with the smooth?creep compensation device in the door area that makes no difference in terms of the operating quality between this?elevator and the regular.

Introduction

The difference with the general passenger elevator

SANEI tower elevator is mainly used in special purpose independent height (100-500 m) structure of the special elevator. The unique design of the traction machine and anti swing. Due to the tension of the wire rope, the door area is designed to compensate for the smooth movement of the device, so that the quality of the elevator and the elevator is no difference.

Integrated control system, open up a new green process

SANEI integrated control system is a new generation of intelligent vector control system integration, integrated dual 32 bit computer system, CAN serial communication, the closed-loop vector control technology, sensor technology, load load compensation starting model PWM dead time compensation technology, the elevator control and drive combined with Canbus, Modus communication will be perfect really, to achieve the integration of the whole device has compact structure, small size, less wiring, higher reliability, more simple operation, more economical.

Permanent magnet synchronous gearless traction machine, set off a new green revolution

Compared with the traditional technology, the permanent magnet synchronous gearless traction machine can save 40% of energy, and does not need to replace oil, oil pollution and low noise.

Matching energy regenerative feedback technology, playing a new green movement

The high purity renewable energy generated, unloading the burden of the grid, to maintain the elevator room normal temperature, prolong the life of the elevator, reduce harmonic pollution, purify the grid environment, the elevator energy consumption reduced by 30%~70%. Improve operating comfort, achieve perfect control.

Parameter Table

Rated?load Persons Drag meth Speed Net dimension of car Dimension of door opening Dimension of?hoistway Dimension of machine room Over head Pit depth
Width Depth Width Height Width Depth Width Depth Height
kg  

V

V

V

F

m/s A B E F C D R T H Q P
450 6 1.0 1400 850 800 2100 1900 1500 2600 3300 2500 4300 1400
630 8 1.0/1.5/1.75 1400 1100 800 2100 1900 1700 2600 3500 2800 4300/4500/4600 1400/1600/1600
800 10 1.0/1.5/1.75/2.0 1400 1350 800 2100 1900 2000 2600 3800 2800 4300/4500?? 4600/4900 1400/1600? 1600/2100
1000 13 1.0/1.6/1.75/2.0 1600 1500 900 2100 2200 2150 3000 4200 2800 4300/4500?? 4600/4900 1400/1600? 1600/2100
1250 16 1.0/1.6/1.75/2.0 1950 1400 1100 2100 2600 2100 3200 4200 2800 4500/4600? 4600/4900 1500/1600? 1700/2200
1600 21 1.0/1.6/1.75/2.0 1950 1750 1100 2100 2600 2600 3500 4500 2800 4500/4600? 4600/4900 1500/1700? 1700/2200

Details PC version

Standard Function

Standard Function Function Description
>Brake detection and protection Open and closed through real-time monitoring of the brake brake arm detection switch. When the brake is not required when opened. The system will not allow the elevator.
>The correction speed and the number of floors of station The system in operation is detected in the end station after the switch. The elevator will force the speed and automatic correction of floor display.
>Limit protector The system detects the limit switch action, will immediately stop the elevator running.
>Maximum protection The system detects the limit switch action, the whole system will immediately power down.
>Overspeed protection When the elevator up and down more than 1.2 times the rated speed, cut off the control power supply, the elevator will stop running.
>Layer station floor, direction display The station shows the elevator floor and the direction to be run.